System Model
|
CE1000-E
|
Inverter Model N3-49.9K
|
N3-50K
|
PV Input
|
Max. Recommended PV Power [Wp]
|
75000
|
Max. PV Input Voltage [V]
|
1000
|
MPPT Voltage Range [V]
|
350 ~ 800
|
Rated PV Input Voltage [V]
|
667
|
Start-up Voltage [V]
|
350
|
No. of MPP Trackers
|
3
|
No. of Input Strings per Tracker
|
2 / 2 / 2
|
Max. PV Input Current [A]
|
36 / 36 / 36
|
Max. Short-circuit Current [A]
|
40 / 40 / 40
|
AC Output
|
Max. AC Output Apparent Power [VA]
|
54890
|
55000
|
Max. AC Output Active Power [W]
|
49900
|
50000
|
Max. AC Output Current [A]
|
79.6
|
80.0
|
Rated AC Output Current [A]
|
72.4
|
72.5
|
Rated AC Output Voltage [V]
|
3 / N / PE, 230 / 400
|
Grid Frequency [Hz]
|
50 / 60
|
Adjustable Power Factor [cos φ]
|
1 (0.9 leading ~ 0.9 lagging)
|
Output THDi (@Rated Output)
|
< 3%
|
AC Input
|
Max. AC Input Apparent Power [VA]
|
54890
|
55000
|
Max. AC Input Active Power [W]
|
49900
|
50000
|
Max. AC Input Current [A]
|
79.6
|
80.0
|
Rated AC Input Voltage [V]
|
3 / N / PE, 230 / 400
|
Grid Frequency [Hz]
|
50 / 60
|
Battery Model BS80-E
|
BS90-E
|
BS100-E
|
Battery Technology
|
LiFePO
|
LiFePO
|
LiFePO
|
Nominal Capacity [Ah]
|
204 (102 * 2)
|
204 (102 * 2)
|
204 (102 * 2)
|
Battery Configuration
|
16S2P * 8
|
16S2P * 9
|
16S2P * 10
|
Nominal Energy [kWh]
|
83.6
|
94
|
104.4
|
Norminal Voltage [V]
|
409.6
|
460.8
|
512
|
Voltage Range [V]
|
358.4 ~ 467.2
|
403.2 ~ 525.6
|
448 ~ 584
|
Max. Continuous Charging / Discharging Current [A]
|
102 / 102
|
102 / 102
|
102 / 102
|
Nominal Power [kW]
|
41.8
|
47
|
52.2
|
Depth of Discharge
|
95%
|
95%
|
95%
|
System General Data
|
Dimensions (with Inverter) (W * H * D) [mm]
|
1330 * 1950 * 1425
|
Dimensions (without Inverter) (W * H * D) [mm]
|
1000 * 1950 * 1425
|
Weight (with Inverter) [kg]
|
1227
|
1313.5
|
1400
|
Weight (without Inverter) [kg]
|
1152
|
1238.5
|
1325
|
Ambient Temperature Range [ ]
|
-20 ~ +55
|
Relative Humidity
|
0 ~ 95%
|
Operation Altitude [m]
|

|
Topology
|
Transformerless
|
Cooling
|
Air-conditioner
|
Fire Protection
|
Aerosol
|
Communication
|
CAN, RS485, USB Update, WiFi, 4G, Ethernet
|
Ingress Protection
|
Cabinet: IP55; Inverter: IP65
|
Cycle Life
|
6000 @90% DOD / 25 / 0.5C
|
Certifications & Standards
|
Grid Regulation
|
EN 50549-1, CEI 0-21, VDE4105, NRS 097-2-1
|
Safety Regulation
|
IEC 62619, EN 62477-1, IEC 62109-1, IEC 62109-2, IEC62477-1, EN 62109-1, EN 62109-2
|
EMC
|
EN / IEC 61000-6-2, EN / IEC 61000-6-4, EN IEC 61000-3-11, EN 61000-3-12
|